Product Category
Labware(2)
Materials Science(360)

Available for Sale

Search term:"Chemical Industry"

Compare Products: Select up to 4 products.

*Please select more than one item to compare

393 matches found for Chemical Industry

Selecting a GC Column for Specific Industries/Applications

We know that only the most accurate analytical products will do. That’s why we offer the Supelco portfolio of analytical GC columns, providing you the accuracy, precision and consistency you need. Gas chromatography, first established in the 1950′s, is a mature analytical technique with many establi...

TLC Analysis of Nitroanilines on HPTLC Silica Gel 60 F 254 with Concentrating Zone

detector (in situ evaluation with TLC/HPTLC scanner (Camag) UV 254) Featured Industry Chemicals and Industrial Polymers suitability application for TLC

TLC Analysis of p-Hydroxybenzoic Acid and p-Hydroxybenzoic Acid Esters on HPTLC Silica Gel 60 RP-18 WF254s

plate HPTLC pre-coated plate RP-18 wF 254s (1.13124.0001) eluent [A] acetone; [B] water; (50:50, A:B) migration distance 7 cm chamber normal chamber without chamber saturation sample 0.1 μL detector in situ evaluation with TLC/HPTLC scanner (Camag) UV 270 nm Featured Industry Chemicals and Industria...

HPLC Analysis of Sulfonamide Positional Isomers on Discovery® Zr-Carbon C18

column Discovery Zr-Carbon C18, 15 cm x 4.6 mm I.D., 3 µm particles (65706-U) column temp. 80 °C mobile phase [A] 10mM diethylamine, pH 10.8; [B] acetonitrile; flow rate 1.5 mL/min injection 5 µL detector UV, 240 nm Categories Analytical Chromatography, Pharmaceutical Analysis, Antibiotics Featured ...

HPLC Analysis of 4-Methyl-5-Phenyl-2-Oxazolidone Enantiomers on Astec® CHIROBIOTIC® TAG

column CHIROBIOTIC TAG, 25 cm x 4.6 mm I.D., 5 µm particles (14024AST) column temp. 23 °C mobile phase methanol flow rate 0.8 mL/min sample 2 mg/mL in methanol injection 2 µL detector UV, 230 nm Categories Analytical Chromatography, Chiral Applications, Organic Bases, Chemicals and Industrial Polyme...

HPLC Analysis of p-Toluenesulfonic Acid (PTSA) and Pyrimethamine on SeQuant ZIC-HILIC

column SeQuant ZIC-HILIC, PEEK, 150 x 4.6 mm, 5 µm, 200 Ã… (1.50455.0001) column temp. ambient mobile phase [A] acetonitrile; [B] ammonium acetate; (90:10, A:B) flow rate 0.5 mL/min injection 1 µL detector 254 nm Featured Industry Chemicals and Industrial Polymers suitability application for HPLC

GC Analysis of Mandelic Acid Methyl Ester Enantiomers on Astec® CHIRALDEX® B-DP

column Astec CHIRALDEX B-DP, 30 m x 0.25 mm I.D., 0.12 µm (78023AST) oven 140 °C carrier gas helium, 30 psi sample peak 1: R(-)-methyl mandelatepeak 2: S(+)-methyl mandelate inj. temp. 250 °C detector FID, 250 °C Categories Analytical Chromatography, GC Applications, Acids, Enantiomers Featured Indu...

HPLC Analysis of Hydrolyzed β-Cyclodextrin on TSKgel® G-Oligo-PW

column TSKgel G-Oligo-PW, 30 cm x 7.8 mm I.D., 6 µm particles (808031) column temp. 60 °C mobile phase distilled water flow rate 1 mL/min detector RI Categories Analytical Chromatography, Carbohydrates, Polysaccharides Featured Industry Chemicals and Industrial Polymers Food and Beverages Legal Info...

TLC Analysis of Chlorophenols on HPTLC Silica gel 60 RP-18 F254s

detector in-situ evaluation with TLC/HPTLC scanner (Camag) UV 265 nm migration distance 7 cm chamber normal chamber without chamber saturation eluent [A] acetonitrile; [B] water; (80:20, A:B) plate HPTLC pre-coated plate RP-18 WF 254s (1.13724.0001) Categories Analytical Chromatography, TLC Applicat...

HPLC Analysis of 5-Methyl-5-Phenylhydantoin Enantiomers on Astec® CHIROBIOTIC® V2

column CHIROBIOTIC V2, 25 cm x 4.6 mm I.D., 5 µm particles (15024AST) column temp. 25 °C mobile phase methanol flow rate 0.48 mL/min sample 1 mg/mL in methanol injection 10 µL detector UV, 220 nm Categories Analytical Chromatography, Chiral Applications, Organic Bases, Chemicals and Industrial Polym...

GC Analysis of β-Butyrolactone Enantiomers on Astec® CHIRALDEX® G-TA

column Astec CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 110 °C carrier gas helium, 30 psi sample peaks 1 & 2: beta-butyrolactone inj. temp. 250 °C detector FID, 250 °C Categories Analytical Chromatography, GC Applications, Esters, Enantiomers, Lactones Featured Industry Chemicals a...

GC Analysis of Glycols on Nukol™

column Nukol, 15 m x 0.53 mm I.D., 0.5 µm (25326) oven 110 °C, 8 °C/min to 220 °C carrier gas helium, 15 mL/min sample 100 ppm each glycol in water injection 1 µL, direct detector FID, 250 °C Categories Analytical Chromatography, GC Applications, Diols, Glycols Featured Industry Chemicals and Indust...

HPLC Analysis of Acrylic Resin on TSKgel® SuperµLtiporeHZ-M vs. TSKgel® SuperHZ

column TSKgel® SuperµLtiporeHZ-M, 15 cm x 4.6 mm I.D., 4 µm particles (821488) column temp. 40 °C mobile phase THF flow rate 0.35 mL/min sample acrylic resin, 0.3% injection 10 µL detector refractive index (RI) Categories Analytical Chromatography, Polymers, coatings, and plastics Featured Industry ...

HPLC Analysis of Acetic Acid on SeQuant ZIC-HILIC

column SeQuant ZIC-HILIC, PEEK, 150 x 4.6 mm, 5 µm, 200 Ã… (1.50455.0001) column temp. ambient mobile phase [A] acetonitrile; [B] ammonium acetate; (80:20, A:B) flow rate 1.0 mL/min injection 50 µL detector 210 nm Categories Analytical Chromatography, Organic Acids Featured Industry Chemicals and In...

HPLC Analysis of Luciferin Enantiomers on CHIRALPAK® AGP

column CHIRALPAK AGP, 10 cm x 4 mm I.D., 5 µm particles (58150AST) column temp. 25 °C mobile phase 10 mM sodium phosphate, pH 6.0 flow rate 0.9 mL/min sample luciferin detector UV, 225 nm Categories Analytical Chromatography, Chiral Applications, Vitamins, Nutraceuticals & Natural Products Featured ...

HPLC Analysis of Structural Isomers on Discovery® Zr-Carbon

column Discovery Zr-Carbon, 15 cm x 4.6 mm I.D., 3 µm particles (65730-U) column temp. 60 °C mobile phase [A] water; [B] acetonitrile; (20:80, A:B) flow rate 0.5 mL/min injection 10 µL detector UV, 254 nm Categories Analytical Chromatography, Semivolatiles Featured Industry Chemicals and Industrial ...

HPLC Analysis of 5-Methyl-5-Phenylhydantoin Enantiomers on Astec® CHIROBIOTIC® TAG

column CHIROBIOTIC TAG, 25 cm x 4.6 mm I.D., 5 µm particles (14024AST) column temp. 25 °C mobile phase methanol flow rate 0.48 mL/min sample 1 mg/mL in methanol injection 10 µL detector UV, 220 nm Categories Analytical Chromatography, Chiral Applications, Organic Bases, Chemicals and Industrial Poly...

GC Analysis of Camphor Enantiomers on Astec® CHIRALDEX® G-DP

column Astec CHIRALDEX G-DP, 30 m x 0.25 mm I.D., 0.12 µm (78033AST) oven 100 °C carrier gas helium, 30 psi sample peaks 1 & 2: camphor enantiomers inj. temp. 250 °C detector FID, 250 °C Categories Analytical Chromatography, GC Applications, Enantiomers, Volatiles Featured Industry Chemicals and Ind...

HPLC Analysis of Organic Acids on Discovery® C18

column Discovery C18, 5 cm x 4.6 mm I.D., 5 µm particles (504947) column temp. 20 °C mobile phase [A] 0.1% TFA in [B] water:methanol; (60:40, A:B) flow rate 2.0 mL/min injection 10 µL detector UV, 254 nm Categories Analytical Chromatography, Organic Acids Featured Industry Chemicals and Industrial P...

HPLC Analysis of 5-Methyl-5-Phenylhydantoin Enantiomers on Astec® CHIROBIOTIC® V

column CHIROBIOTIC V, 25 cm x 4.6 mm I.D., 5 µm particles (11024AST) column temp. ambient mobile phase ethanol flow rate 1.5 mL/min sample 4 mg/mL in methanol injection 5 µL detector UV, 254 nm Categories Analytical Chromatography, Chiral Applications, Organic Bases, Chemicals and Industrial Polymer...

HPLC Analysis of Lactic Acid Enantiomers on Astec® CLC-L and CLC-D

column Astec CLC-L and CLC-D, 15 cm x 4.6 mm I.D., 5 µm particles (53023AST, 53123AST) column temp. 25 °C mobile phase 5 mM copper sulfate flow rate 1 mL/min injection 10 µL detector UV, 254 nm Categories Analytical Chromatography, Chiral Applications, Chemicals and Industrial Polymers, Organic Acid...

HPLC Analysis of Urea on SeQuant ZIC-HILIC

column SeQuant ZIC-HILIC, PEEK, 50 x 4.6 mm, 5 µm, 200 Ã… (1.50451.0001) mobile phase [A] acetonitrile; [B] ammonium acetate 5 mM; (90:10, A:B) flow rate 0.5 mL/min injection 5 µL detector 204 nm Categories Analytical Chromatography, Amines Featured Industry Chemicals and Industrial Polymers Life Sc...

TLC Analysis of Polyvalent Phenols on HPTLC NH2 F254s (analyte set 2)

plate HPTLC pre-coated plate NH2 F 254s (1.13192.0001, 1.15647.0001) eluent [A] chloroform; [B] methanol; (50:50, A:B) migration distance 7 cm chamber normal chamber without chamber saturation sample 0.2 μL detector in situ-evaluation with TLC/HPTLC scanner (Camag) UV 254 nm Featured Industry Chemic...

GC Analysis of β-Butyrolactone Enantiomers on Astec® CHIRALDEX® B-DP

column Astec CHIRALDEX B-DP, 30 m x 0.25 mm I.D., 0.12 µm (78023AST) oven 140 °C carrier gas helium, 30 psi sample peaks 1 & 2: beta-butyrolactone inj. temp. 250 °C detector FID, 250 °C Categories Analytical Chromatography, GC Applications, Esters, Enantiomers, Lactones Featured Industry Chemicals a...

HPLC Analysis of 4-Phenyl-2-Oxazolidinone Enantiomers on Astec® CHIROBIOTIC® T2

column CHIROBIOTIC T2, 25 cm x 4.6 mm I.D., 5 µm particles (16024AST) column temp. 25 °C mobile phase methanol flow rate 1 mL/min sample 1 mg/mL in methanol injection 2 µL detector UV, 254 nm Categories Analytical Chromatography, Chiral Applications, Organic Bases, Chemicals and Industrial Polymers,...

GC Analysis of α-Bromo-γ-Butyrolactone Enantiomers on Astec® CHIRALDEX® G-DP

column Astec CHIRALDEX G-DP, 30 m x 0.25 mm I.D., 0.12 µm (78033AST) oven 160 °C carrier gas helium, 30 psi sample peaks 1 & 2: alpha-bromo-gamma-butyrolactone enantiomers inj. temp. 250 °C detector FID, 250 °C Categories Analytical Chromatography, GC Applications, Esters, Enantiomers, Lactones Feat...

GC Analysis of Δ-Decanolactone Enantiomers on Astec® CHIRALDEX® G-TA

column Astec CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven helium, 24 psi carrier gas helium, 24 psi sample peaks 1 & 2: delta-decanolactone enantiomers inj. temp. 250 °C detector FID, 250 °C Categories Analytical Chromatography, GC Applications, Esters, Enantiomers, Lactones Featured...

GC Analysis of Formalin Solution on Carboxen®-1006 PLOT

column Carboxen-1006 PLOT oven 200 °C carrier gas 3.0 mL/min sample Formalin solution injection 0.5 µL detector TCD Categories Analytical Chromatography, GC Applications, Solvents, Aldehydes, Alcohols Featured Industry Chemicals and Industrial Polymers Legal Information Carboxen is a registered trad...

HPLC Analysis of Various Polymers on TSKgel® SuperµLtiporeHZ-H

column TSKgel SuperµLtiporeHZ-N, 15 cm x 4.6 mm I.D., 6 µm particles (821885) column temp. 40 °C mobile phase THF flow rate 0.35 mL/min sample each polymer, 3 mg/mL injection 10 µL detector refractive index (RI) Categories Analytical Chromatography, Polymers, coatings, and plastics Featured Industry...

HPLC Analysis of Polyethylene Glycol 200 on TSKgel® G-OLIGO-PW

column TSKgel G-OLIGO-PW, 30 cm x 7.8 mm I.D., 6 µm particles (808031) mobile phase distilled water flow rate 1 mL/min detector RI Categories Analytical Chromatography, Glycols, Diols Featured Industry Chemicals and Industrial Polymers Legal Information TSKgel is a registered trademark of Tosoh Corp...